10pcs/tray, 180pcs/cartons, carton size: 40*30*15cm, 24cartons a pallet
High-strength cartons, good for long-distance export transport
Classification by delay method
According to the different delay modes, time relays can be divided into two types: power-on delay type and power-off delay type.
(1) The power-on delay type time relay starts to delay immediately after receiving the input signal. After the delay is completed, its execution part outputs the signal to manipulate the control circuit; when the input signal disappears, the relay immediately restores to the state before the action .
(2) The power-off delay time relay is just the opposite. When the input signal is obtained, the execution part immediately has an output signal; but after the input signal disappears, the relay needs a certain delay to restore to the state before the action.
Ordering Information |
1: If I want buy small quantity , how can I get it ?
A: We have distributor in UK, USA, Morocco, Malaysia, Germany and Ireland, you just tell me your where are you from, I can recommend my office to contact you
2: What the warranty period ?
A: 6 month.
3: Can I brand the items with our own logo/Brand?
A: Welcome OEM and ODM.
4: Can you do design for me?
A: We have experienced designers, according to your requirement, we can add your company logo, website, phone number or any of your ideas on the products or on the box… Just tell me your ideas, and let me do it for you.
Automotive micro relay appliance
Models | TKB2B | TKB4B | |
Rated supply voltage | 120VAC, 230VAC 50/60Hz; DC24V | ||
Operating voltage range | Rated voltage 85-110% (90%-110% is DC12V) | ||
Power consumption | 3.5W | ||
Max. output load | 5A, 250 VAC (p.f.=1) | 3A, 250 VAC (p.f.=1) | |
Min. output load | 10 mA, 17 VDC | ||
Repetitive error | ±2% (FS max.) | ||
Setting error | ±5% (FS max.) | ||
Voltage error | ±2% (FS max.) | ||
Temperature error | ±2% (FS max.) | ||
Resetting time | Min. time: 0.2 sec | ||
Insulation resistance | 100MΩ (DC500V) | ||
Dielectric strength | Between current-carrying and Non-current-carrying parts 2000V 50/60Hz min | ||
Between control output terminals and operating circuit1500V 50/60Hz min | |||
Between contacts 1000V 50/60Hz min | |||
Vibration resistance | Destruction | 10~55Hz with 0.75mm single amplitude each in 3directions for 2 hours each | |
Malfunction | 10~55Hz with 0.5mm single amplitude each in 3 directions for 10 minutes each | ||
Shock resistance | Destruction | 30G | |
Malfunction | 10G | ||
Ambient temperature | -10ºC~55ºC | ||
Ambient humidity | 35%~85%RH | ||
Life expectancy | Mechanical | >107 (under no load, at 1,800 operations/hour) | |
Electrical | >105 | ||
Weight | Approx. 60g |