10pcs/tray, 180pcs/cartons, carton size: 40*30*15cm, 24cartons a pallet
High-strength cartons, good for long-distance export transport
Ordering Information |
1: How do you control the products’ quality?
A: Auto inspection machine and manual testing together before packing.
2: Would you accept to use our logo?
A: If you have good quantity, we can make OEM for you.
3: May i have your product catalog and price list ?
A: Yes, please send an email to our sales team for product catalog and price list.
4: How do you control the quality?
A: 100% Auto inspection machine and manul testing together before packing.
We have a full range of laboratories, UL witnesses and TUVlaboratories, excellent equipment such as: high speed cameras, X-ray analyzers, so that we can carry on resistive loads, lamp loads and motor loads.
We have fully functional laboratory, our laboratory is UL witnessed laboratory & CANS laboratory, we can done resistive load, lamp load, and motor load in our laboratory.
Models | TKB2B | TKB4B | |
Rated supply voltage | 120VAC, 230VAC 50/60Hz; DC24V | ||
Operating voltage range | Rated voltage 85-110% (90%-110% is DC12V) | ||
Power consumption | 3.5W | ||
Max. output load | 5A, 250 VAC (p.f.=1) | 3A, 250 VAC (p.f.=1) | |
Min. output load | 10 mA, 17 VDC | ||
Repetitive error | ±2% (FS max.) | ||
Setting error | ±5% (FS max.) | ||
Voltage error | ±2% (FS max.) | ||
Temperature error | ±2% (FS max.) | ||
Resetting time | Min. time: 0.2 sec | ||
Insulation resistance | 100MΩ (DC500V) | ||
Dielectric strength | Between current-carrying and Non-current-carrying parts 2000V 50/60Hz min | ||
Between control output terminals and operating circuit1500V 50/60Hz min | |||
Between contacts 1000V 50/60Hz min | |||
Vibration resistance | Destruction | 10~55Hz with 0.75mm single amplitude each in 3directions for 2 hours each | |
Malfunction | 10~55Hz with 0.5mm single amplitude each in 3 directions for 10 minutes each | ||
Shock resistance | Destruction | 30G | |
Malfunction | 10G | ||
Ambient temperature | -10ºC~55ºC | ||
Ambient humidity | 35%~85%RH | ||
Life expectancy | Mechanical | >107 (under no load, at 1,800 operations/hour) | |
Electrical | >105 | ||
Weight | Approx. 60g |