Available for 1 and 2 poles, a variety of high capacity models
High sensitive of consumed power 400mW
With up to 8mm ofinsulation distance between coil and contacts
High insulation with 10kv of shock resistant voltage
Meet with the ambienttemperature 85℃
Richiedi un preventivo

Series name:R2G
Contact form:1, 2 (A: NO, B: NC, C: CO)
Terminalarrangement:
O:3.5mmcontactpinpitch1pole12A
U:5.0mmcontactpinpitch1pole12A
H:5.0mmcontactpinpitch1pole16A,2poles8A
Coil voltage code:
| Code | 005 | 006 | 009 | 012 | 048 | 060 | 110 |
| voltage(V DC) | 5 | 6 | 9 | 12 | 48 | 60 | 110 |
| Code | 524 | 615 | 730 | ||||
| voltage(V AC) | 24 | 115 | 230 |
Material Level:Blank: B class:
Coil Consumption:Blank: Standard (400mW)
Encapsulation Way:Blank: Sealed
| Contatto | Configuration | 1C/1A | 2C/2A | |
| Carico | Resistive load (AC-1) | 12A,16A/250VAC,30VDC | 8A/250VAC,30VDC | |
| Motor load (AC-15) | 1/2HP, 240VAC;3/4HP,120VAC | 1/3HP,240VAC,1/4HP,120VAC | ||
| Max. switching capacity (resistive) | 3000VA,360W;4000VA,480W | 2000VA,240W | ||
| Min. switching capacity | 170mW(17V/10mA) | |||
| Resistenza di contatto iniziale | ≤100mΩ | |||
| Materiale | Lega di Ag | |||
| Electrical durability (110% rated voltage,85℃) |
3.5mm: 1NO 12A; 1NC 6A ≥100000 C Cycles(85ºC) | 5.0mm: 2NO 8A; 2NC 4A ≥100000 Cycles(85ºC) | ||
| 5.0mm: 1NO 16A; 1NC 8A ≥100000 Cycles(85ºC) | ||||
| Electrical Durability (Normal temperature) |
3.5mm: 1NO 12A; 1NC 12A ≥5×10000 Cycles(23ºC) | 5.0mm: 2NO 8A; 2NC 8A ≥5×10000 Cycles(23ºC) | ||
| 5.0mm: 1NO 16A; 1NC 16A ≥3×10000 Cycles(23ºC) | ||||
| Durabilità meccanica | Dc≥5000×10000 Cycles (18000 Ops/h); AC≥3000×10000 Cycles (18000 Ops/h) |
|||
| Pick-up voltage (23℃) (Rated voltage) |
DC≤70% | |||
| Drop-out voltage (23℃) (Rated voltage) |
DC:≥10% | |||
| Maximum voltage (23℃) (Rated voltage) |
1.3 | |||
| Resistenza di isolamento | ≥1000 MΩ (500 VCC) | |||
| Potenza operativa della bobina | DC(W) | approx. 0.43 | ||
| AC(VA) | approx. 1 | |||
| Operate time | ≤10ms | |||
| Release time (at nominal voltage) |
≤5ms | |||
| Initial breakdon voltage | Tra contatti aperti | 1000VAC/1min (leakage current 1mA) | 1000VAC/1min (leakage current 1mA) | |
| Tra i poli | _ | 2500VAC/1min (leakage current 1mA) | ||
| Tra contatti e bobina | 5000VAC/1min (leakage current 1mA) | 5000VAC/1min (leakage current 1mA) | ||
| Insulation characteristics CEI 60664UL840 |
Tensione nominale | 3 | ||
| Livello di inquinamento | 250 V CA | |||
| Livello di sovratensione | III | |||
| Tensione nominale V.CC | 5 | 6 | 9 | 12 | 24 | 48 | 60 | 110 |
| Coil resistance Ω | 62.5 | 90 | 200 | 360 | 1440 | 5220 | 8570 | 28800 |
| Nominal voltage V.AC | 24 | 115 | 230 | |||||
| Coil resistance Ω | 350 | 8100 | 23800 |
Coil resistance: under coil voltage 110V are measured with tolerance of ±10%Ω, above 110V with tolerance of ±15%Ω.