1.In addition to UP and Down models, a reversible(Up-Down)counter is also available.
2.Maximum counting speed of 1000cps, never before attained by a small-size preset counter. Models with memory backup function against power failure available.
3.Power supply freely selectable within a range of 100 to 240VAC.
Also, power supply for the DC-operated models is selectable within a range of 12 to 48 V.
Ordering Information |
1: What about your after-sale service?
A: We reply every enquiry within 24 hours and try our best to meet the demand of the customers ,will consult and follow the relevant sales and handlings.
2: How to pay my order?
A: 30% deposit first, 70% balance will be paid before shipping.
3: Can I become an agent / distributor of products?
A: Welcome! However, please let me know your country / region first, we will check it, and then we can talk about it. If you need other cooperation, please feel free to contact us.
4: How can I get the catalog?
A: You can click to visit my company website: www.shenler.com ; Then select download electronic directory to view it.
Models | TMC7-QL | TMC7-QH | TMC7-YL | TMC7-YH | |
Supply Voltage | AC100-240V 50/60HZ DC12-48V(contains 20% ripple Max.) | ||||
Operating voltage range | 85-110% of the rated voltage | ||||
Power consumption | Approx.4W(AC 240V 50Hz),4W(DC48V) | ||||
CP1, CP2 Max Counting Speed | 30 cps: (contact and transistor inputs) Min. pulse width:16.7 ms (ON/OFF ratio:1:1) | ||||
1K cps(transistor inputs) Min pulse width:0.5 ms (ON/OFF ratio:1:1) | |||||
Reset System | Power-OFF reset: Reset time 0.5s, Reset time following power application 0.05s External reset & manual reset: Rest time 0.02s, Reset time following signal application: 0.05s. |
||||
Signal Input | Count and Reset | ||||
Input methods | Contact | ||||
Impedance by short-circuiting contacts: 1kQ Max Residual voltage: 2V Max impedance by opening contacts: 100kQ min |
|||||
Control Output | 5A 250VAC COSD=1 SPDT(1C) | ||||
Operating Mode | Up-counting | Down-counting | |||
Display | 7-segment LEDs | ||||
Ambient Temperature | -10°C-55°C | ||||
Storage Ambient Temperature | -25°C-65°C | ||||
Ambient Humidity | 35-85%RH | ||||
Insulation Resistance | 100MQ(DC500V) | ||||
Dielectric Strength | 2000VAC, 50/60Hz for 1 min(between current-carrying terminal and exposed noncurrent carrying metal parts and between no-continuous contacts) | ||||
Static Immunity | Malfunction 8kv | ||||
Impulse Withstand Voltage | 6kv(between power terminals) | ||||
6kv (between the current-carrying terminal and exposed non-current-carrying metal parts) | |||||
Vibration resistance | Destruction | 10-55Hz,0.75mm single amplitude | |||
Malfunction | 10-55Hz, 0.5mm single amplitude | ||||
Shock resistance | Destruction | 20G | |||
Malfunction | 10G | ||||
Ambient temperature | -10ºC ~ 55ºC | ||||
Ambient humidity | 35% ~ 85%RH | ||||
Life expectancy | Mechanical | 10 million operations min. | |||
Electrical | 100,000 operations min. | ||||
Protection grade | TEC: IP40(only for panel) | ||||
Weight | approx. 60g |