24v 36s Timer Relay - Shenler Relay 24v 36s Timer Relay - Shenler Relay
HOME > Timer > 24v 36s Timer Relay
24v 36s Timer Relay
24v 36s Timer Relay

24v 36s Timer Relay

Features

10pcs/tray, 180pcs/cartons, carton size: 40*30*15cm, 24cartons a pallet
High-strength cartons, good for long-distance export transport

certificate Request A Quote

Share Our Social

Adjustable Delay Timer Relay Details

The main function of the time relay is as an executive device in simple program control. When it receives the start signal, it starts timing. After the timing is over, its working contacts open or close to promote the subsequent circuit work. Generally speaking, the delay performance of the time relay can be adjusted within the range of design, so that it is convenient to adjust the length of its delay time. A time relay alone may not be able to start delayed closing. After closing for a period of time, it will open again. First realize the delayed closing and then delay the opening, but in general, by configuring a certain number of time relays and intermediate relays It can be done.

TKB Ordering Information
TKB22

FAQ:

1: How do you shipping?
A: FOB Nanjing or CIF.

2: What should I do if the quality is damaged?
A: If there is any damage, the customer can confirm it with a photo, and once it is free, it will not be free or the damage will be reduced.

3: How many R&D person in your factory ?
A: So far we have 20

4: Are they UL approved?
A: Yes, we have.

Automotive micro relay appliance

RKE4CO

Our workshops have clean control, dust free, constant temperature and humidity. Everyone should on the anti-static clothes when enter workshop.

Characteristics

Models TKB2B TKB4B
Rated supply voltage 120VAC, 230VAC 50/60Hz; DC24V
Operating voltage range Rated voltage 85-110% (90%-110% is DC12V)
Power consumption 3.5W
Max. output load 5A, 250 VAC (p.f.=1) 3A, 250 VAC (p.f.=1)
Min. output load 10 mA, 17 VDC
Repetitive error ±2% (FS max.)
Setting error ±5% (FS max.)
Voltage error ±2% (FS max.)
Temperature error ±2% (FS max.)
Resetting time Min. time: 0.2 sec
Insulation resistance 100MΩ (DC500V)
Dielectric strength Between current-carrying and Non-current-carrying parts 2000V 50/60Hz min
Between control output terminals and operating circuit1500V 50/60Hz min
Between contacts 1000V 50/60Hz min
Vibration resistance Destruction 10~55Hz with 0.75mm single amplitude each in 3directions for 2 hours each
Malfunction 10~55Hz with 0.5mm single amplitude each in 3 directions for 10 minutes each
Shock resistance Destruction 30G
Malfunction 10G
Ambient temperature -10ºC~55ºC
Ambient humidity 35%~85%RH
Life expectancy Mechanical >107 (under no load, at 1,800 operations/hour)
Electrical >105
Weight Approx. 60g